These update instructions are for SQ-420 Sensors that are no longer working after an automatic update: If you are experiencing any difficulties with these instructions or your sensor is still not making measurements, please contact you experience problems with Apogee software, please fill out this form so our engineers can address the issue as soon as possible. NOTE: To use additional devices, open a second ApogeeConnect software window, plug in the additional sensor, and enter the serial number into the prompt. The sensor should begin working in a few seconds, and the “Device Connected” indicator will turn green and show the serial number. Step 6: Start the ApogeeConnect software and enter the 4 digit serial number of your sensor into the pop-up window (found on the white label 6-12” from the USB plug). Click next, and the driver should install properly. Right click this device and select “Update Driver Software,” then “Browse my computer for driver software.” Navigate to the ApogeeConnect folder, then the select the “driverlib” folder. Please open your device manager, which should have a com port device “SQ-420” with a yellow box and an “!.” If this is not present, please unplug your sensor for 3 seconds, then reconnect. *If your computer says USB Device not recognized you need to install drivers (Note, for sensors with a serial number greater than 1258 should the latest version. *Select the SQ420_V2.txt from the file dialog box. Step 5: Start the software, which will result in a pop-up window prompting you to update the firmware in your sensor, please do so. Step 4: If the software is open after installation, close the software, then plug in your SQ-420 sensor. Step 3: Run the downloaded setup file (from Step 1) to install the new software, following the prompts. Step 2: If you can, uninstall you current USB quantum software using the control panel, it should be named “SQ420.” Click here to get the latest software version > Step 1: Download the ApogeeConnect setup file to your computer, this should default to your downloads folder. If you don’t have a previously installed copy of the software, do not worry about writing this information down. This can be found by plugging in your sensor, opening the current software, and navigating to the calibration window. Please write down your calibrated multiplier and offset before updating the firmware.After installing the new software, in order to update the firmware, the sensor needs to be plugged in BEFORE the newly installed software is opened for the firmware update prompt to appear.The sensor firmware can only be updated on a Windows based PC or tablet, after updating it will work on both Windows and Mac. Important things to know before beginning update process: If needed uninstall the HDI device and install a new driver. Steps performed: Uninstall the old software, install the new software, update the sensor firmware. If your sensor is no longer working after an automatic update, click here >Ĭlick here for BTM300 update instructions > SQ-420 Update Instructions (Serial Number less than 1258): All of the newest sensors are labeled SQ-420X. Please note this refers to very old sensors purchased prior to March 2016. These update instructions are for SQ-420 Sensors with a serial number less than 1258.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |